Cầu đo điện trở tiếp xúc Model MMR-630

Index:WMGBMMR630   The MMR-630 Series meters are professional portable instruments for measuring very low resistances. Due to their special measurement algorithm they can be used for both resistive and inductive type of a specimen that makes MMR-630 series perfect instruments for electricians testing electrical ju ...


Index:WMGBMMR630
The MMR-630 Series meters are professional portable instruments for measuring very low resistances. Due to their special measurement algorithm they can be used for both resistive and inductive type of a specimen that makes 
MMR-630 series perfect instruments for electricians testing electrical junctions, motors and power transformers windings. The results can be stored in the internal memory and send to a computer via serial interface. A quick PASS/FAIL test function with results displayed and acoustically indicated simplifies measurements considerably. 

MMR-630 Technical Specifications
Measurement of resistive object type:
  • - welded and soldered connections, equipotential bonding, earth wire,
    - terminals and connectors, rail welded joints, cables and wires,
    - measurement  4-pole method.
  • Measurement of inductive object type:
    - coils (motors and transformers), low resistance coils.
  • Range selection autoranging or manual (measurement of inductive object type).
  • Selectable measurement mode adjusted to object type:
    - for resistive objects - fast mode (3 seconds),
    - for inductive objects - long mode with automatic discharge after measurements (or with lower accuracy - shorter mode).
  • Selectable measurement mode adjusted to application:
    - normal mode - after pushing „START” button,
    - automatic mode - since test leads are connected to the object meters automatically starts measurement with dual direction current flow and gives average result - what eliminates eventual DC voltage on tested object,
    - continuous mode - every 3 seconds for resistive objects or continuous measurement for inductive objects.
  • Window mode:
    -  this option enables setting an upper and a lower limit between which the average measurement result is bound to appear. The results outside of this range will be indicated by two long audible signals and the symbols.
  • MMR-630 is designated not to be effected by interference up to 20mV and to show noises from 20 to 100mV (so in edge conditions even 5 times higher than measured drop of potential).
  • Memory store for up to 990 results and a communications facility for  transferring data from the device to a PC.

Electric security:
- type of insulation: double, according to EN 61010-1 and IEC 61557
- measurement category: CAT III 300V acc. to EN 61010-1
- protection class acc. to EN 60529: IP54

Other technical data:
- meter’s power supply: battery package SONEL/Ni-MH 4,8V
- battery charging time: approx. 2,5 hours
- number of measurements with the current of 10A: 300
- auto-off time: 120 seconds
- immunity to interference: additional error ≤1% for voltage 50 Hz ≤100mV RMS
- maximum leads resistance for the 10A current: 0,1Ω
- maximum inductance of the tested object: 40H
- accuracy of the test current: ±10%
- resistance measurement time:
    - with the selected resistive object type with the bidirectional current:     3 seconds
    - with the selected inductive object type, dependant on the resistance 
      and inductance of the object:     a few minutes (max. 10)
- dimensions: 295 x 222 x 95 mm
- weight: approx. 1,7 kg

Rated operational conditions:
- operation temperature: 0...+40°C
- storage temperature: -20...+60°C

MMR-620 microohmmeter conforms the following directives 
or standards according to CE requirements.

Directive:
Low Voltage Directive (LVD) 73/23/EEC, 93/68/EEC.

Standards: 
   
EN 61010-1:2001 Safety requirements for electrical equipment for measurement, control and laboratory use. General requirements .
EN 61010-031:2002: Safety requirements for electrical equipment for measurement, control and laboratory use. Safety requirements for hand-held probe assemblies for electrical measurement and test.

Directive: 
   
Electromagnetic compatibility (EMC) 89/336/EEC, 92/31/EEC, 93/68/EEC.

Standards:

EN 61326:1997+A1:1998+A2:2001 Electrical equipment for measurement, control and laboratory use - EMC requirements.

Resistance measurement

MMR-630Current Accuracy
RangeResolution
0...999,9μΩ0,1μΩ 10A 
±(0,25%  m.v. + 2 digits)
1,0000...1,9999mΩ0,0001mΩ
2,000...19,999mΩ0,001mΩ
20,00...199,99mΩ 
0,01mΩ
1A 
200,0...999,9mΩ 
0,1mΩ
 0,1A
1,0000...1,9999Ω 
 0,0001Ω
 2,000...19,999Ω0,001Ω
10mA 
 20,00...199,99Ω0,01Ω 
0,1mA 
 200,0...1999,9Ω 0,1Ω 0,1mA

- input impedance of the voltmeter: ≥200kΩ

„m.v.” - measured value.

 
 
Relate Product
Cầu đo điện trở tiếp xúc Model MMR-630
Cầu đo điện trở tiếp xúc Model MMR-630
Cầu đo điện trở tiếp xúc Model MMR-620
Cầu đo điện trở tiếp xúc Model MMR-620
 
Sản phẩm mới
MENTOR 12 Hợp bộ thử Rơ Le 3 pha kỹ thuật số
MENTOR 12 Hợp bộ thử Rơ Le 3 pha kỹ thuật số
MATRIX Thiết bị đo Karota giếng khoan
MATRIX Thiết bị đo Karota giếng khoan
SuperSting R8 IP Máy đo điện trở phân cực kích thích
SuperSting R8 IP Máy đo điện trở phân cực kích thích
Hỗ trợ trực tuyến
Kinh doanh
Kỹ thuật
Skype

Số lượt truy cập : 787774
Số người trực tuyến : 2